LED Functions
The following table describes LED Funtions
Defrost LED
Permanently on: defrost active
Flashing: manual defrost active
O: otherwise
Alarm LED
Permanently on: alarm active
Flashing: alarm acknowledged
O: otherwise
Evaporator LED
Permanently on: fans active
O: otherwise
Compressor LED
Permanently on: compressor active
Flashing: a delay, a protection or a
locked start-up
O: otherwise
Aux LED
Permanently on: Aux output
active
O: otherwise
°C LED
Permanently on: display the
temperature
O: otherwise
NOTE: When switched on, the device performs a Lamp Test; the
display and LEDs will ash for several seconds to check that they all
function correctly.
C-Series Models
Model Temp Range
HC24R 33° - 42° F
HA24BB 33° - 48° F
HA24WB 45° - 65° F
DIAL TEMPERATURE CONTROL
ADA-Compliant Models
(Excludes ADA Freezer - HA24F models use digital controller
found on page 5)
C
O
O
L
E
R
OFF
1
2
3
4
5
6
COLD
Figure 3. Dial Temperature Controller
Use a straight slot screwdriver to adjust the dial
temperature control. The control is located at the top rear
panel of the cabinet. Approximate temperature ranges are
as follows:
ADA-Compliant Series
Model Temp Range
HA24RB 33° - 42° F
HA24BB 35° - 48° F
HA24WB 45° - 65° F
Adjust the temperature as follows:
Colder Temperature:
Turn the adjusting screw clockwise (to the right).
Warmer Temperature:
Turn the adjusting screw counterclockwise (to the left).
Temperature Control OFF:
Turn the adjusting screw completely counterclockwise to
the OFF position until a click is heard.
NOTE: The condenser fan motor turns o with the compressor.