use and_care_guide

PERLICK RESIDENTIAL INSTALLATION MANUAL
6
perlick.com
LED Functions
The following table describes LED Funtions
DIGITAL TEMPERATURE CONTROL
C-Series Models
Figure2.nEW961DigitalTemperatureController
To Change Setpoint Temperature
1. Press . “SP will be displayed. Press again to display
current setpoint temperature.
2. Press and to modify it and or to save the
change.
On/O
To turn the unit o, press and hold for at least 5 seconds.
“OF” will be displayed. To turn the unit on again, press and hold
for at least 5 seconds.
Perlick C-Series units come standard with digital control.
Programming Button Denitions:
Defrost LED
Permanently on: defrost active
Flashing: manual defrost active
O: otherwise
Alarm LED
Permanently on: alarm active
Flashing: alarm acknowledged
O: otherwise
Evaporator LED
Permanently on: fans active
O: otherwise
Compressor LED
Permanently on: compressor active
Flashing: a delay, a protection or a
locked start-up
O: otherwise
Aux LED
Permanently on: Aux output
active
O: otherwise
°C LED
Permanently on: display the
temperature
O: otherwise
STAND-BY (ESC)
Press and release
• Returns to the previous
menu level
• Conrms parameter value
Press for at least 5 sec.
• Activates the Standby
function (o) (When
outside the menus)
SET (ENTER)
Press and release
• Opens Machine Status menu
and displays alarms (if active)
Press for at least 5 sec.
• Opens Programming menu
• Conrm commands
UP
Press and release
• Scroll menu items
• Increases values
Press for at least 5 sec.
• Activates the Manual
Defrost function
DOWN
Press and release
• Scroll menu items
• Decreases values
Press for at least 5 sec.
• Function can be congured
by the user
NOTE:Dependentonthemodelandconguration,thecontrollers
havebeenprogrammedtoonlyallowatemperatureadjustment
withinaspeciedrange.Seethechartbelowforthespeciedrange
allowedforyourunit.
NOTE:Whenswitchedon,thedeviceperformsaLampTest;the
displayandLEDswillashforseveralsecondstocheckthattheyall
functioncorrectly.
C-Series Models
Model Temp Range
HC24RB 33° - 42° F
HC24BB 33° - 48° F
HC24WB 45° - 65° F
DIAL TEMPERATURE CONTROL
ADA-Compliant Models
(ExcludesADAFreezer-HA24Fmodelsusedigitalcontrollerfound
onpage5)
C
O
O
L
E
R
OFF
1
2
3
4
5
6
COLD
Figure3.DialTemperatureController
Use a straight slot screwdriver to adjust the dial temperature
control. The control is located at the top rear panel of the
cabinet. Approximate temperature ranges are as follows:
ADA-Compliant Series
Model Temp Range
HA24RB 33° - 42° F
HA24BB 35° - 48° F
HA24WB 45° - 65° F