Installation Manual HP15 HP24 HP48 HH24 HC24 HA24 15” SIGNATURE SERIES 24” SIGNATURE SERIES 48” SIGNATURE SERIES SIGNATURE SERIES SOTTILE C-SERIES ADA-COMPLIANT SERIES Form No. Z2348-D Rev. 09.01.
PERLICK RESIDENTIAL INSTALLATION MANUAL TABLE OF CONTENTS Warranty Information ..................................................................2 Door Information.............................................................................8 Safety Information..........................................................................4 Changing the Door Swing Direction..................................8 Plumbing, Electrical and General Information..............4 Handle Installation......................
PERLICK RESIDENTIAL INSTALLATION MANUAL REMEDY: Perlick will provide the parts and labor necessary to repair or replace (at Perlick’s option) any parts proven to be defective in material or workmanship during the Basic Warranty Period. Perlick will provide the replacement parts, but not the labor, for any parts of the hermetically sealed refrigeration system proven to be defective in materials or workmanship during the Extended Warranty Period.
PERLICK RESIDENTIAL INSTALLATION MANUAL SAFETY PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING and CAUTION information in the manual. The information is important for the safe and efficient installation, operation and care of your Perlick unit. DANGER Indicates a hazard that WILL result in serious injury or death if precautions are not followed.
PERLICK RESIDENTIAL INSTALLATION MANUAL DANGER Serious Electrocution Hazard! Electrical grounding is required. This appliance is equipped with a 3-prong (grounding) polarized plug for your protection against possible shock hazards. Failure to comply with these electrical guidelines may result in possible death or serious injury, fire, or loss of property. • Never remove the round grounding prong from the plug. • Never use a 2-prong adapter. • Never use extension cord to connect power to the unit.
PERLICK RESIDENTIAL INSTALLATION MANUAL PREPARING THE SPACE CAUTION If the unit is to be installed under a countertop, it is recommended that the countertop be supported by a structure other than the unit itself to prevent damage to the unit. 2).
PERLICK RESIDENTIAL INSTALLATION MANUAL TOE PLATE INSTALLATION Once the unit is secured in place, install the louvered toe plate. Secure the plate by snapping the latch into the latch catch on the unit (Figure 5). CAUTION The toe plate must be removed to service the unit. The floor cannot interfere with removal, and the louvered sections must not be covered or obstructed. Obstructions could prevent proper air circulation, which may damage the unit.
PERLICK RESIDENTIAL INSTALLATION MANUAL SHELVING/DRAWER ADJUSTMENTS CAUTION Completely empty shelf or drawer before removing. 1. Pull the shelf/drawer out to its furthest position. Locate the tabs in the middle of both extenders. Lift one tab up while pushing the opposite tab down, and pull shelf/ drawer out (Figure 6). 2. Position each bracket separately. Grasp the middle of the bracket, pull the front end up and out, then forward to remove it. 3. Place bracket at desired location.
PERLICK RESIDENTIAL INSTALLATION MANUAL 5). Using the screws removed in step 3, install the top and bottom hinge brackets from the kit (Fig. 9). Figure 7. Door Removal Figure 9. Hinge Installation 6). Remove the top and bottom door hinge brackets and the push plunger brackets (Fig. 10). Retain the screws for later use. Figure 10. Door Brackets Figure 8. Hinge Removal perlick.
PERLICK RESIDENTIAL INSTALLATION MANUAL 7). Remove the front panel from the door assembly by removing the door gasket and then removing the overlay mounting screws, 4 per side, from the perimeter of the door assembly (Fig. 11). Rotate the front panel 180°. The top becomes the bottom. Reattach using the same screws and mounting holes and then reinstall the door gasket. 9). Insert the bearing into the door hinge bracket (Fig. 13). 10).
PERLICK RESIDENTIAL INSTALLATION MANUAL 12). Place the lower V-block into the lower cabinet hinge with the notch parallel to the cabinet (Fig. 15). HANDLE INSTALLATION The handle mounting on the wood CAUTION overlay should be mounted on the overlay only (not the actual door) to avoid damage to the factory door. 1. Handle must be attached to the overlay before mounting the overlay onto the door. Mark the rear of the wood overlay panel with handle fastening locations. 2.
PERLICK RESIDENTIAL INSTALLATION MANUAL WOOD OVERLAY INSTALLATION (FOR -2, -4 AND -6 MODELS) Before beginning installation, check all components for proper fit and finish. CAUTION For best performance and functionality, the overlay panels should be 3/4” thick. The weight of the overlays should not exceed 20 lbs for solid (-2) doors, 10 lbs for glass (-4) doors, or 10 lbs for drawer (-6) models. WINE RACK TRIM (OPTIONAL) All wine reserve racks come with sleek stainless steel fronts.
Use and Care Guides, Specification Sheets, Wood Overlay Templates for Doors, Drawers and Grilles, and Corresponding Compliance and Energy Guides are available for download at www.perlick.com/residential-products/service-support. Contact Perlick Customer or Technical Service at 800.558.5592. Customer Service and Technical Service are available business days Monday through Friday from 7:00 a.m. to 7:00 p.m. CST. 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • info@perlick.com • www.perlick.
Installation Manual for Beer Dispensing Equipment HP15TS/TO HP24TS/TO HC24TB/TO HP15TS-3-**A HP24TS-3-***A 15” SIGNATURE SERIES 24” SIGNATURE SERIES 24” C-SERIES 15” SIGNATURE SERIES ADARA 24” SIGNATURE SERIES ADARA Form No. Z2349-B Rev.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT CONGRATULATIONS Congratulations on your purchase of a Perlick high quality residential Beer Dispenser. Perlick has proudly manufactured beer dispensing systems for over 50 years for bars, restaurants, stadiums, arenas and large venues around the world. That same technology is used in each and every residential beer dispenser we produce, assuring you’ll pour fresh, cold beer as the brewery intended it to be enjoyed.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT INSTALLATION OF DISPENSING EQUIPMENT Open the tapping kit box and become familiar with its components. The instructions on pages 4 through 10 will demonstrate how to properly install the tapping equipment on your new Perlick Beer Dispenser.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT INSTALLATION OF DISPENSING EQUIPMENT Open the tapping kit box and become familiar with its components. If the dispensing head is going to be mounted on a counter top directly above the refrigerated cabinet, have the counter top pre-drilled using the supplied template on page 11. Make sure that the access hole in the refrigerated cabinet is in line with the counter top holes.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT Figure 3. Figure 4. 2. Remove air “T” from end of air tube by loosening fastener holding the two halves together. Remove the air tube from the tower being careful not to damage the product tube. 3. Cut air tube at mark made in step 1. Re-install air tube into tower and re-install “T” on the end of the air tube so “T” faces the rear of the tower. 4.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 1. Locate the dispensing head , black beer line(s), and hose clamp(s). Slide one end of each beer line onto the stainless steel tubes which protrude out the bottom of the dispensing head and clamp tight. 2. Remove transit tape with a utility knife around the hole in the top of the unit from both inside and outside of the cabinet. Gently punch out foam w/screwdriver and remove.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 4. Install the Air Scoop Kit. Start by removing the upper set of screws located above the fan on the back wall of the cabinet. 5. Assemble components from the kit as follows – Insert black snap bushing into air scoop mounting bracket, then insert one end of the air snorkel through the snap bushing. A zip tie can be inserted behind the mounting bracket to keep the tube in place.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 7. If installing a two faucet system, a CO2 manifold will need to be installed. Locate the red CO2 lines, CO2 manifold and a #10 x 1/2” sheet metal screw. Slide one end of each hose onto the barbed fittings on the manifold and clamp. On the left rear side wall of the beer compartment there is a double row of screws which run vertically. Remove one of the two top screws and discard.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 10. On the right rear sidewall there is a double column of screws. Remove the left screw. Locate the safety chain and a #10 x 1/2” sheet metal screw from the parts bag. Insert the screw through the closed end link of the chain and tighten in the vacant screw hole. The chain can now be used to secure the tank with “S” hook, preventing damage to the regulator. 11. CO2 tanks are shipped empty and must be filled prior to use.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 13. Before tapping, make sure the beer faucet is closed. To tap a keg, insert the coupler into the neck of the barrel. Turn the coupler clockwise until it stops (about an 1/8 turn), then push down on the top of the coupler and again turn clockwise until it stops. Your barrel is now tapped. Open the CO2 valve on the regulator as well as the valve on the manifold if used. CONNECTING THE REGULATOR TO THE CO2 CYLINDER 1.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT MOUNTING HOLE TEMPLATE FOR DRAFT ARMS AND ADARA SIGNATURE TOWERS NOTE: The hole placement for the Draft Arm and Adara towers are the same even though the decorative flanges are different shapes. perlick.
Use and Care Guides, Specification Sheets, Wood Overlay Templates for Doors, Drawers and Grilles, and Corresponding Compliance and Energy Guides are available for download at www.perlick.com/residential-products/service-support. Contact Perlick Customer or Technical Service at 800.558.5592. Customer Service and Technical Service are available business days Monday through Friday from 8 a.m. to 4:30 p.m. CST. 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • info@perlick.com • www.perlick.