Series Manual

22
PGS TROUBLESHOOTING GUIDE
No Flame
Gas Shut off
Obstruction in Orifice(s)
Leak in Gas Train
No Gas in Tank or Not Connected to Gas Source
Low Flame
Leak in Gas Train
Obstruction in Orifice(s) or venturi’s
Natural Gas valve only turned part way
Burner gasket plugging venturis.
High Flame
Wrong Orifice Size for style Gas
Venturi Air shutter needs adjustment
Burner split
Flames out the Control Panel
Spider webs in Venturi tubes see page 20
Valve knobs won’t turn
Spider fire burnt out lubrication in valve
Lubrication dried out
Warped or bubbled Lower
Casting
Burner burnt out and emitting too much flame in one
area melting casting.
Burner left on for extended period of time
Wrong rock in casting causing build up of heat and
melting casting
Venturi tubes not lined up with gas valves
Stainless Steel rusting
Grill placed near pool chemicals
Paint peeling
Aluminum Base sprinkler/animal urine/chemicals
Grill won’t light w/module
No sound from Module replace battery
Slight sound cracked electrode or crack in wire -
After dark look for spark
Electrode Missing from
Collector box
Electrode clip gave way and electrode fell out
Upper casting tipping or not
fitting
Holes for hinge pins are uneven, casting rear edge
bowed or uneven