Service manual

1. To remove the LSP assembly from the bottom tray, release the 2 locks in the
middle on each side rail by moving the tab backward and at the same time pull
the complete assembly backward.
2. Hook the bracket in the first row of holes in the cabinet bottom (in other words,
reposition the bracket from [1] to [2]).
3. Do the same with the 'DW/3D comb' module (reposition from [3] to [4]).
Service Position 2:
To make the copper side of the LSP accessible, follow these steps:
1. Disconnect the degaussing cable and rotation coil cable (cable between mains
assembly and LSP must be long enough, otherwise this mains assembly must
also be removed from the cabinet).
2. Remove the DAF panel assembly (see explanation later in this chapter), and
remove the DAF panel out of the assembly.
3. Remove the Side I/O panel from its assembly and place it on the bottom tray.
4. Remove the 3D comb filter panel and DW panel out of the mechanical bracket,
and reconfigure the cabling.
5. Remove the HD jack panel assembly. The HD jack panel itself must stay
connected to the LSP.
6. Release the cables from their cable ties.
7. Carefully shift the LSP panel backward, and shift it a bit to the left (as seen from
the back).
8. Turn the LSP assembly clockwise, and position the hook of the LSP assembly in
the groove of the bottom tray. This is not a true service position, but the LSP
assembly position is stable, assuming a big enough table is used.
9. Position the DW panel and 3D comb panel carefully on top of the LSP and also
position the HD jack panel and DAF panel on the bottom, guarding against short-
circuiting the panels.