Service manual

How to navigate
When you press the 'MENU' button on the RC transmitter, the set toggles between the
SDM and the normal user menus (with the SDM mode still active in the background).
When you press the 'STATUS/EXIT' button on the RC transmitter, the set shows/hides
the error buffer. To prevent interference with oscilloscope measurements, it is possible
to hide the OSD.
How to exit
Switch the set to STANDBY by pressing the power button on the remote control
transmitter or via the 'POWER' switch of the set.
Service Alignment Mode (SAM)
Purpose
To perform alignments.
To change option settings.
To display/clear the error code buffer.
Specifications
Software alignments (see chapter 8).
Option settings (see chapter 8).
Error buffer reading and erasing. The most recent error code is displayed on the
left side.
Hours counter (in hexadecimal format)
Software version.