Service manual

By a combination of automatic diagnostics and an interactive question/answer
procedure, ComPair will enable you to find most problems in a fast and effective way.
Beside fault finding, ComPair provides some additional features like:
Emulation of the (European) Dealer Service Tool (DST).
If both ComPair and SearchMan / Force (Electronic Service Manual) are
installed, all the schematics and the PWBs of the set are available by clicking on
the appropriate hyperlink.
Example: Measure the DC-voltage on capacitor C2568 (Schematic/Panel) at the
Monocarrier.
Click on the 'Panel' hyperlink to automatically show the PWB with a highlighted
capacitor C2568.
Click on the 'Schematic' hyperlink to automatically show the position of the highlighted
capacitor.
How to Connect
1. First install the ComPair Browser software (see the Quick Reference Card for
installation instructions).
2. Connect the RS232 interface cable between a free serial (COM) port of your PC
and the PC connector (marked with 'PC') of the ComPair interface.
3. Connect the AC power adapter to the supply connector (marked with 'POWER
9V DC') on the ComPair interface.
4. Switch the ComPair interface OFF.
5. Switch the television set OFF (remove the AC power).
6. Connect the ComPair interface cable between the connector on the rear side of
the ComPair interface (marked with 'I
2
C') and the ComPair connector on the
mono carrier (see figure 5-6).