Error Codes
In case of non-intermittent faults, clear the error buffer before starting the repair. This is
to ensure that 'old' error codes are not present.
If possible, check the entire content of the error buffer. In some situations, an error code
is only the result of another error code (and not the actual cause). For example, a fault
in the protection detection circuitry can also lead to a protection.
Table: Error Code Table
Error
Device Description Def. item Diagram
1 FBX 3V3 prot FBX 3V3 protection 5703 B3
2 No HFB No Horizontal Flyback
3323 B4
3
X-Ray
protection
X-Ray protection 3310 B4
4 5V protection 5V protection 1200/7651
A7/B6
5 No HOP POR Startup failure B4
6
General I2C
bus error
General I2C bus error
1943 A7
7 Mains Dip error
HW error
8 3D comb prot 3D comb prot Black box C0/C1
10 MC24C32
NVM communication
error
7012 B7
11 MC24C32
NVM identification
error
7012 B7
12 SAA5667
Main uP, int. RAM
test failure
7001 B7