Owner manual

2005-12-12 Page 19
6 TROUBLE SHOOTING
This chapter describes the action to take if the Inca camera
does not operate correctly or how to receive support.
6.1 KNOWN PROBLEMS USING THE INCA
When using the Micro D to Sub D cable (8122 410 81530)
that is also included into the starter kit please notice that
the point 5 and 7 are interchanged all other points are
interconnected one to one.
The cleanness of the sensor is of major importance for the
image quality. During the production of the Inca special
account is taken with respect to the cleanness of the
sensor. However when you remove the sensor protection
cap from the Inca front end prior to the mounting of the
lens, the sensor can attract some dust or dirt. This pollution
can affect the image captured with the Inca. Remove the
sensor protection cap only in a clean environment by
holding the Inca with the sensor facing down. After
removing the sensor protection cap inspect the cleanness
of the sensor and immediate assemble the required lens to
the Inca.
In case of a red blinking system LED (see 2.4.2 System
LED) during booting one of the following files are probably
missing on the flash file system; ‘RapIB320Lcm.rbf’ or the
appropriate license file Rhapsody.key or Clicks.key. These
files are required when you like to use the Inca either
under Rhapsody or Clicks software control.