Datasheet

https://www.phoenixcontact.com/us/products/2801161
04/04/2017Page2/6
Lightning/surge arrester type 1/2-VAL-MS-T1/T2 1000DC-PV/2+V-
FM-2801161
Technical data
Dimensions
Width 53.4 mm
Depth 65.5 mm
Horizontal pitch 3 Div.
Ambient conditions
Degree of protection IP20 (only when all terminal points are used)
Ambient temperature (operation) -40 °C ... 80 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude ≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation) 5 % ... 95 %
Shock (operation) 60g (Half sine/11 ms/3x XYZ)
Vibration (operation) 7.5g (5-500 Hz/2.5 h/XYZ)
General
IEC test classification PV I / II
PV T1 / T2
EN type T1 / T2
SPD failure behavior OCM (Open-circuit mode)
Connection configuration Y configuration
Installation location Inside
Accessibility Accessible
Installation location of the disconnect device Internal
Mode of protection (L+) - (L-)
(L+) - PE
(L-) - PE
Mounting type DIN rail: 35 mm
Color jet black RAL 9005
Housing material PA 6.6-FR
PBT-FR
Degree of pollution 2
Distance between live and grounded parts 8 mm
Flammability rating according to UL 94 V-0
Design DIN rail module, two-section, divisible
Surge protection fault message Optical, remote indicator contact