Operation Manual

The MIU injection-ignition system carries out
checks on the rpm counter and the electric fan for
radiator cooling.
The MIU control unit has a decoder for the anti-
theft immobiliser.
The MIU control unit is connected to a diagnostic
LED on the instrument panel, that also carries out
the deterrent flashing functions.
The MIU control unit power supply is furthermore controlled by the emergency switch; that is to provide
further safety for the scooter.
Precautions
Troubleshooting hints
1 A fault in the MIU system could most likely be due to the connections and not the components.
Before troubleshooting the MIU system, carry out the following checks:
A: Electrical power supply
a. Battery voltage
b. Blown fuse
c. Remote controls
d. Connectors
B: Chassis earthing
C: Fuel supply
a. Broken fuel pump
b. Dirty fuel filter
D: Ignition system
a. Faulty spark plug
b. Broken coil
c. Broken shielded cap
E: Intake circuit
a. Dirty air filter
b. Dirty by-pass circuit
c. Faulty Stepper motor
F: Other
a. Incorrect distribution timing
b. Wrong idle mixture
c.Incorrect reset of the throttle valve position sensor
2 MIU system faults may be caused by loose connectors. Make sure that all connections have been
correctly made.
MP3 250 i.e. Injection
INJEC - 5