Operation Manual

Specification Desc./Quantity
9 Fuel injector
10 Lambda sensor
11 Electric fan starter
The ignition system is integrated with the injection and is of the inductive high efficiency type.
The control unit manages two important parameters:
- Ignition advance
This is optimised according to the engine rpm, to the engine load, temperature and ambient pressure
With idle engine, it is optimised to obtain the stabilisation of the speed at 1450 ± 50 R/1'.
- Magnetisation time
The coil magnetisation time is controlled by the control unit. The ignition power is increased during the
engine start-up.
The injection system recognises the 4-stroke cycle and therefore, ignition is only controlled during
compression.
Specific tooling
020331Y Digital multimeter
Check the efficiency of injection load 15 A fuse No.
5.
Check the efficiency of live control unit power sup-
ply 7.5A fuse No. 10 .
Check there is voltage between pins 22 and 26 of
the interface wiring for around two seconds when
switching to «ON».
MP3 250 i.e. Injection
INJEC - 33