Operation Manual

Reset should be performed in the following cases:
- on first fitting.
- if the injection control unit is replaced.
N.B.
THE TPS RESETTING PROCEDURE MUST NOT BE CARRIED OUT WITH A USED THROTTLE
BODY BECAUSE POSSIBLE VALVE WEAR AND STOP WEAR FOR THE MINIMUM OPENING
MAKE THE AIR FLOW DIFFERENTLY FROM THAT OF PRE-CALIBRATION.
Given that the TPS resetting is also done when the
control unit is replaced, place the control unit - filter
box bellows at 45° during the refitting operation as
shown in the photograph.
Lambda probe
SIGNAL CONTROL
Install the electronic control unit interface wiring.
Start the engine and warm up until the electric fan
switches on.
Use an analogue multimeter with a direct voltage
scale measuring down to 2 V.
Place the tips of the multimeter between pins 4 (-)
and 11 (+)
Injection MP3 250 i.e.
INJEC - 40