LEAK TESTING - GENERAL
Although gas connections on the grill are leak tested prior to shipment, a complete
leak test must be performed at the installation site. Before each use, check all gas
connections for leaks using the procedures listed below.
If the smell of gas is detected at any time, you should immediately check the entire
system for leaks.
BEFORE TESTING
Make sure all packing materials have been removed from the grill, including the
burner tie-down straps.
WARNING
Check all gas supply fittings for leaks before each use. Do not use the grill until all connections
have been checked and do not leak. Do not smoke while leak testing. Never leak test with an
open flame.
Make a solution of one part liquid detergent and one part water. You will need a
spray bottle, brush, or rag to apply the solution to the fittings. For the initial leak
test, make sure the Liquid Propane cylinders is full.
TO TEST
1. Turn the burner valves off.
2. Turn the Liquid Propane cylinder valve counterclockwise to open the valve.
3. Apply a soap solution to all gas fittings. Soap bubbles will appear where a leak
is present.
4. If a leak is present, immediately turn the gas supply "OFF" and tighten leaky
fittings.
5. Turn the gas back "ON" and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply
"OFF" and contact customer service.
7. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be
replaced prior to use.
Only those parts recommended by the manufacturer should be used on the grill.
Substitutions will void the warranty.
12
13
 
WARNING
Do not store grill indoors unless the cylinder is disconnected. Do not store cylinder in a
building, garage, or any other enclosed area, and keep out of reach of children at all times.
INSTALLER FINAL CHECK
Maintain specified clearance of 36 inches from combustible materials and
construction
All internal packaging has been removed.
The hose and regulator are properly connected to the Liquid Propane cylinder.
The unit has been tested and is free of leaks.
The gas supply shutoff valve has been located.
All burners are installed.
Keep the instruction manual for future reference.
WARNING
1. The grill and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressure in excess of
1/2-in. PSI (3.5kpa).
2. The outdoor cooking gas appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure testing of the gas
supply piping system at test pressure equal to or less than 1/2-in. PSI (3.5kpa).
WARNING
1. Do not store spare Liquid Propane cylinders under or near this appliance.
2. Never fill the cylinder beyond 80 percent capacity.
3. If the information in item 1&2 is not followed exactly, a fire causing death or serious
injury may occur.