Use and Care Manual

The user interface includes touch sensitive buttons for operation of the
Port-A-Cool Islander. The user interface also includes status indicator
LEDs and a 7-segment LED display to show the cooling unit’s status.
Power
The green Power LED is illuminated when the
unit is plugged in.
Water level
The red water level LED is illuminated when
the oat switch detects a low water level and
the pump is not turning on. This LED ashes if the
pump is running during a low water occurrence to
indicate that more water needs to be added in order
to continue running the pump.
Timer
The controller features ve pre-programmed modes which
control the fan / pump sequence for a pre-dened period. The
LED ashes slowly if continuously held and ashes quickly if the
timer is enabled and then the Pump or Fan buttons
are continuously held, prompting the user to turn o
the timer in order to exit fan and pump operation.
The green Timer LED is illuminated when the Timer
button is activated. Each touch of the program but-
ton cycles through the ve modes: 1HR, 2HR, 4HR, 8HR, and TIMER
OFF. During the program run, the user can adjust the maximum fan
speed with the up/down buttons. When the program is active, the
Timer LED will be on and, for ve seconds, the user will be shown
which program (1H, 2H, 4H, or 8H) is active.
Pump
Press the pump button once to power on and again to power
o. The green Pump LED is illuminated when the pump is
enabled. The LED ashes slowly if continuously held and
the timer is disabled.
Fan
When the fan is o, touch the fan button once to turn the
fan on in full speed. When the fan is on,
touch of the Fan button again to turn the
fan o. The green Fan LED is illuminated when the fan
is active. The LED ashes slowly if continuously held
and the timer is disabled.
Speeds
The buttons control the air velocity of
the unit. Beginning with “Lo”, or 50%
air ow, up to “Hi” or 100% airow and
increasing in ve percent increments.
7-Segment LED Display
LEDs are used to display the status of
the cooling unit. The LED ashes slowly
if continuously held and ashes quickly if the timer is
enabled and then the Pump or Fan buttons are continuously held,
prompting the user to turn o the timer in order to exit fan and pump
operation.
Two digits display the unit’s temperature, fan speed, and timer pro-
gram. If the unit does not have a temperature sensor connected, the
display will constantly show fan speed. If the unit does feature a tem-
perature sensor, then the temperature is displayed unless: a fan speed
change is being called upon either by means of the up/down button
or by the timer’s program. When a fan speed change is requested, the
fan speed will be displayed for ve seconds before returning to the
unit temperature.
LOCK OUT FEATURE
If the operator would like to lock settings so that they can’t be adjusted,
simply press the “up” arrow and the fan button simultaneously to lock
the controls. To unlock, press the “down” button and the fan icon. When
enabled, “L-E”, or “Lock Enabled”, will be displayed in the LED.
1
2
3
4
5
6
7
LED Speed Display.
“HI” or “LO” or %
CFM will be
illuminated.
LED Timer Display.
Shows one of the 5
modes: 1HR, 2HR,
4HR, 8HR, or OFF.
LED Temp Display.
Temperature of the
internal cooled air in
Fahrenheit or Celcius.
HURRICANE® 3600 USER INTERFACE
PRE-PROGRAMMED TIMER FUNCTION
1) PUMP STARTS (INCLUDES FIVE SECOND DELAY TO ALLOW
WATER TO START REACHING THE PADS)
2) FAN STARTS AT 100% (HI) SPEED (A “KICK START” FOR BEST
VARIABLE SPEED MOTOR OPERATION)
3) FAN RAMPS DOWN TO 50% SPEED
4) FAN RAMPS UP TO FULL SPEED IN 10% STEPS AT ONE MINUTE
INTERVALS (BEGIN INCREASING AIRFLOW AS THE PADS WET OUT
FOR BEST EFFICENCY)
5) FAN RUNS AT MAXIMUM SPEED FOR THE DURATION OF THE
TIMER SETTING (100% SPEED IS DEFAULT, OR IT CAN BE WHAT-
EVER THE USER SELECTS)
6) PUMP SHUTS OFF WHEN TIMER SETTING EXPIRES
7) FAN RAMPS DOWN TO 50% SPEED
8) FAN RUNS 30 MINUTES (PAD DRYING PERIOD)
9) FAN SHUTS OFF
2
1
3
4
5
6
7