Use and Care Manual

MAINTENANCE & STORAGE
Very little maintenance is required on the PORT-A-COOL® unit. Cleanliness is the most important part of
a maintenance program. Keeping the unit clean will do more than any other single item to keep your unit in
peak operating condition. The rugged, corrosion-resistant construction of the unit and industrial grade com-
ponents ensure low maintenance characteristics. In excessively dusty or dirty environments, optional filters
are available from your distributor or at www.port-a-coolparts.com
Daily Maintenance
Daily maintenance is an operational routine rather than actual maintenance. On a daily basis, the pump
should be turned off approximately 15 minutes before the fan is turned off. This will allow the cooling pads
to dry out and extend their life. This also helps to control the growth of mildew, mold, bacteria and other
odor causing elements.
Weekly Maintenance
At the end of the week or at a scheduled time, the unit should be shut down and the sump tank should
be drained. Closing the Spray Bar Adjustment Valve and opening the Drain Valve will accomplish this.
If desired, a hose may be attached to the Drain Valve to direct the drained water to a remote disposal
area. Once the Drain Valve is open, starting the pump will drain the unit. When the pump has removed
most of the water, a small amount will be left in some areas. The PAC2KCYC01, PAC2KCYC01A, PACCYC02,
PACCYC02A, PACCYC03, PACCYC04, PACJS1600, PACJS2400, PACHR3600, and PAC163SVT models come
equipped with a drain plug. Removal of the drain plug will accomplish the same results without the use of
the pump.
Once the sump is drained and the power disconnected, the pads may be removed to allow inspection
and cleaning of the sump tank. Dust may collect in the sump tank over time. This dirt, and any remaining
water, may be vacuumed out using a wet/dry shop vacuum and wiped clean with a cloth. Also, inspect and
clean the Inlet Strainer located on the bottom of the pump. Replace pads in correct airflow direction, refer-
ring to the label on the pads.
Storage
1) Drain all water from the sump tank and clean, ensuring that the pads and sump are completely dry.
2) Roll up the electrical power cord and secure it to ensure that it will not be rolled over, tripped over, or
caught in equipment.
3) Cover the unit completely to prevent dust build-up and store in a dry area. This also helps to prevent damage
to the pads. Optional dust covers are available from your distributor or at www.port-a-coolparts.com.
CAUTION — DISCONNECT POWER BEFORE REMOVING
COOLING PADS FROM THE PORT-A-COOL® UNIT!
NOTICE — POWER CORD MAY BE REPLACED ONLY BY THE
MANUFACTURER OR QUALIFIED AGENT!
PORT-A-COOL OWNER’S MANUAL • PAGE 11