Use and Care Manual

UNIT OVERVIEW
SETUP
Unpacking the PORT-A-COOL® unit.
PORT-A-COOL® units are shipped completely assembled. The PAC2K482S, PAC2K361S, PACHR3600,
PAC2K363S, PAC2K36HPVS, PAC2K24HPVS, PAC163SVT, PACJS1600, PACJS2400, PAC2KCYC01, PAC2KCYC01A,
PACCYC04, and PACCYC04A models ship on a plastic pallet with a cover box strapped over the unit. Cut the
straps and remove the box by lifting it over the unit. Remove the protective plastic dust cover and lift the unit
off the pallet.
Models PAC2K163SHD, PAC2K16HPVS, PACCYC02 , PACCYC02A, PACCYC03, and PACCYC03A are shipped
in an enclosed corrugated box and need only to be removed from the box.
Connecting the water and electricity.
Water Connection
PORT-A-COOL® UNIT MUST BE IN UPRIGHT AND LEVEL POSITION
Locate the brass hose adapter on the side of the PORT-A-COOL® unit (all models except PAC163SVT)
near the water adjustment and drain valves. Verify that the hose washer is in position and in good condition.
Attach a standard garden hose to the brass hose adapter and tighten to preclude leaks. Turn water on to fill
the sump tank.
On models equipped with a manual water fill and sight tube, the water tank in the lower portion is
designed to be filled at a remote location and can be used without a water hose connected. Simply fill the
lower tank using the sight tube as a gauge.
UNIT IS EQUIPPED WITH 50 PSI WATER REGULATOR. DO NOT BYPASS.
WATER INLET PRESSURE SHOULD NOT EXCEED 50 PSI MAXIMUM
Visually inspect water connections for leaks and verify that the connections are secure. Remove the pads
by following the instructions in this owners manual. Once the sump tank is filled, the water flow should cease
and the inlet connections may now be visually checked for leaks. All of these inspections have been per-
formed at the factory but shipping may have caused connections to loosen. Replace the pads by reversing the
removal operation.
PAGE 2 • PORT-A-COOL OWNER’S MANUAL
SAFE OPERATION
To reduce the risk of electric shock, re or injury:
Do not operate any unit with a damaged cord or plug. Discard unit or return to an authorized
service facility for examination and/or repair.
Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings.
Arrange cord away from trac area where it will not be tripped over.
Read instructions and labels carefully.
Always unplug the electric cord to the Port-A-Cool unit before performing inspections or repairs.
Plug into three-prong grounded GFCI protected electrical receptacle only.
Do not operate if there is any damage to the plug or cord.
Do not step on or roll over power cord with heavy or sharp objects.
Do not operate unit unless all pads are securely in place.
Remove the plug from the electrical receptacle by pulling on the plug and not the cord.
Test the GFCI receptacle or breaker monthly to ensure it is functioning properly.
Do not operate near open containers of ammable liquids or gases.
Ensure evaporative cooler pumps are running continuously to saturate and wet combustible media when used
in close proximity to open ame or spark producing activities. A distance of at least 35 feet away from open
ame or sparks is recommended to ensure safe operation.
Never wash the unit cabinet with a garden hose; water may harm the motor and electrical system.
If the unit is damaged or it malfunctions, do not continue to operate it. Refer to the warranty,
troubleshooting or FAQ section, call Port-A-Cool, LLC, Technical Support at 1-888-266-5243, or email