CUSTOMER RESPONSIBILrrlEs TABLE
MAINTENANCE TASK
Check oil level
Change oil
Clean Air Filter .Assembly
Check Spark Plug
Prepare Unitfor Storage
Before Every 25
each Hours of
use Every
Season
X See Note 2
x
x
Every 50 Every 100
Hours of Hours of
Every Every
Season Season
See Note I
X
Prepare unit for storage if it is to remain
idle for more than 30 days.
Note 1: Change oil after firsttwo (2) operating hours and every 50 operating
hours thereafter, more often if operated inextreme dusty or dirty conditions.
Note 2: Check oil after 5 hours of operation.
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been subjected to
operator abuse or negligence. To receive full value from the warranty,operator
must mai_ain the generator as instructed in this manual.
ENGINE MAINTENANCE
Refer to the EngineOperator's manual for service and maintenance of the
engine.
GENERATOR MAINPENANCE
Your generator should be kept clean and dry at alltimes, The generator should
not be stored or operated in environmentsthat includes excessivemoisture,
dust or any corrosive vapors. If these sub_ancas are on the generator, clean
with a cloth or soft bristle brush, Do not use a garden hose or anythingwith
water pressure to clean the generator. Water may enter the cooling air slots and
could possibly damage the rotor, stator and the internal windings of the gen
head.
GROUND FAULT CIRCUIT INTERRUPTER GFCI RECEPTACLE)
MONTHLY: For maximum protection against eleotricelshockthe GFCI should
be tested monthly,
To test:
1. Depress the TEST button. "me RESET button should extend. If the RESET
button does not extend, notify a DeVIIbiasAir Power Company Authorized
Warranty Service Center.
2. To restore power, depress the RESETbutton firmlyinto the GFCI unit until an
audible click is heard. If reset properly, the RESET bufton is flush with the
surface of the test button. When the button stays in, the bower is ON.