Manual

If you are going to store your generator for more than 30 days, use the
following infon'natron as a gurde to prepare the generatorfor storege.
Never store generator with fuel in the tank indoors or in
enclosed, poorly ventilated areas, where fumes can reach
an open flame, spark or pilot light as on a furnace, wafer heater, clothes
dryer or other gas appliances.
ENGINE PREPARATION
1. Add fuel stabilizer to fuel tank to minimizethe formation of fuel gum
deposits during storage.
2. Run engine at lasst 10 minutes after adding stabilizerto allow it to enter the
fuel system,
3. Next shutoff engine,
4. Disconnect the spark plug wire and remove the spark plug,
5. Add one tasspoon of oil through the spark plug hole,
6. Place mg over spark plug hole and pull the recoil a few times to lubricate
the combustion chamber.
7. I_eplace the spark plug, but do not connect the spark plug wire.
NOTE: If a fuel stabilizer isnot used, all gasoline must be drained from the tank
and carburetor to prevent gum deposits from forming on these parts and causing
possible malfunction of the engine.
GENERATOR
, Clean the generator as outlined in the Maintenance Section on this manual.
. Check that cooling airslotsand openings on generater are open and
unobstructed.
BATTERY
. Store battery as dasonbed by the bsttery manufacturer.
NOTE: After storing battery for a long pedod of time it may lose its charge, If
the battery loses its charge, manually start the enginewith the battery connect-
ed. The engine will recharge the battery as it runs.
lYENG D2_525