Specification

ORDERING INFORMATION
LD6B EU6B 6LBW 6LBM 6LBN
ENERGY DATA
Sound Rating: Class A standards
(Values at non-dimming line voltage)
Minimum Starting Temperature: -30°C (-22°F)
EMI/RFI: FCC Title 47 CFR, Part 15, Class B (Consumer)
Input Voltage: UNV (120V - 277V)
Power Factor: >0.90
(at nominal input 120-277 VAC & 100% of Rated Output Power)
Input Frequency: 50/60Hz
1000 Lumen D010 1500 Lumen D010
Input Power: 11W THD: <14% Input Power: 15.5W THD: <13%
120V Input Current: 0.09A 277V Input Current: 0.04A 120V Input Current: 0.13A 277V Input Current: 0.06A
2000 Lumen D010 3000 Lumen D010
Input Power: 21.2W THD: <9% Input Power: 27.6W THD: <10%
120V Input Current: 0.18A 277V Input Current: 0.08A 120V Input Current: 0.23A 277V Input Current: 0.10A
4000 Lumen D010 5000 Lumen D010TE
Input Power: 41.6W THD: <13% Input Power: 57.9W THD: <14%
120V Input Current: 0.35A 277V Input Current: 0.15A 120V Input Current: 0.49A 277V Input Current: 0.22A
6000 Lumen D010TE 7000 Lumen D010TE
Input Power: 59.7W THD: <14% Input Power: 75.8W THD: <13%
120V Input Current: 0.50A 277V Input Current: 0.22A 120V Input Current: 0.64A 277V Input Current: 0.29A
120V 277V
Lumens Inrush (A) Duration (ms) Inrush (A) Duration (ms)
1000 Lumen D010 1.02 0.041 2.18 0.021
1500 Lumen D010 1.02 0.042 2.24 0.064
2000 Lumen D010 1.02 0.077 2.43 0.027
3000 Lumen D010 1.15 0.067 3.26 0.027
4000 Lumen D010 1.2 0.088 3.9 0.03
5000 Lumen D010TE 5.1 0.132 10.2 0.153
6000 Lumen D010TE 5.4 0.123 10.8 0.154
7000 Lumen D010TE 4.9 0.13 9.8 0.156
ENERGY
SAMPLE NUMBER: LD6B15D010EMBOD
Housing
Lumens
1
Voltage Driver Options
LD6B=LED Downlight
6” Nominal
Aperture
LD6BCP=LED
Downlight
6” Nominal
Aperture,
Chicago
Plenum
10=1000 lumens
15=1500 lumens
20=2000 lumens
30=3000 lumens
40=4000 lumens
50=5000 lumens
10
60=6000 lumens
10
70=7000 lumens
10
Blank=120-277V
3=347V (step down
transformer)
1000 - 4000 Lumen
D010=0-10V Dimming, 1% to 100%, 120V-277V
D010TR=0-10V or Line Voltage Dimming, 5% to 100%, 120V-277V
DE010=0-10V Dimming, 0% to 100%, 120V-277V
D5LT=Fifth Light® (DALI) Dimming, 0% to 100%, 120V-277V
DMX=DMX/RDM Dimming, 0% to 100%, 120V-277V
14
DL2=Lutron® Hi-Lume Forward Phase Dimming, 1% to 100%, 120V
Only
DL3=Lutron® Hi-Lume 3 Wire Dimming, 1% to 100%, 120V-277V
DLE=Lutron Ecosystem dimming 1% to 100%, 120V-277V
5000, 6000, and 7000 Lumen
D010TE=0-10V 1% or Trailing Edge, 10% to 100%, 120V-277V (120V
Only for Trailing Edge Dimming)
1000 - 3000 Lumen
DLV=Low voltage dimming driver (1-100%) for use with DLVP system
(3000 lumen and below)
3,15
Tunable white 1000-2000 Lumens
16
1DE010W2N2050=0-10V dimming, 0% to 100%, 120V, 2000K - 6500K
1DE010W2N2765=0-10V dimming, 0% to 100%, 120V, 2700K - 5000K
1D5LTW2N2050=Fifth Light (DALI), 0% to 100%, 120, 2000K - 6500K
1D5LTW2N2765=Fifth Light (DALI), 0% to 100%, 120V, 2700K - 5000K
2DE010W2N2050=0-10V dimming, 0% to 100%, 277V, 2000K - 6500K
2DE010W2N2765=0-10V dimming, 0% to 100%, 277V, 2700K - 5000K
2D5LTW2N2050=Fifth Light (DALI), 0% to 100%, 277V, 2000K - 6500K
2D5LTW2N2765=Fifth Light (DALI), 0% to 100%, 277V, 2700K - 5000K
EMBOD=Bodine® Emergency Module with
Remote Test Switch
3
EM7=7W Emergency Module with Remote
Test Switch
3, 4
EM14=14W Emergency Module with Remote
Test Switch
3, 4
IEMBOD=Bodine® Emergency Module with
Integral Test Switch
3
IEM7=7W Emergency Module with Integral
Test Switch
3, 4
IEM14=14W Emergency Module with Integral
Test Switch
3, 4
EMV7=7W Low Voltage Emergency Module
with Remote Test Switch
3,4
EMV14=14W Low Voltage Emergency Module
with Remote Test Switch
3,4
IEMV7=7W Low Voltage Emergency Module
with Integral Test Switch
3,4
IEMV14=14W Low Voltage Emergency
Module with Integral Test Switch
3,4
SWPD1=Factory installed WaveLinx tilemount
daylight sensor (includes control module,
sensor, cable, and tile mount)
3, 15
LWTPD1=Factory installed LumaWatt Pro
wireless sensor kit
3, 15
SAMPLE NUMBER: 6LBM1LIE
Trim
Distribution
5
Flange Finish Options
6LB=6” LED N=Narrow (30° Beam), Spun Aluminum
M=Medium (50° Beam), Spun Aluminum
W=Wide (75° Beam), Spun Aluminum
S=Shallow (75° Beam), Spun Aluminum
12
PS=Non-Conductive Shallow (75° Beam), Injection Molded white
11, 12
CS=Cast Shallow (75° Beam), Die Cast Aluminum
BA=Baffle (50° Beam), Spun Aluminum
7
0=White Polymer
Trim Ring
1=Self-flanged
13
2=White Painted
Self-flanged
LI=Specular Clear
9
H=Semi-Specular
Clear
9
WMH=Warm Haze
9
WH=Wheat
9
GPH=Graphite Haze
9
B=Specular Black
9
MW=Matte White
MB=Matte Black
8
MMS=Matte Metallic
Silver
8
E=Integral Emergency Test
Switch Hole
6
Accessories
HSA6=Slope Adapter for 6” Aperture Housings, Specify Slope
TRM6=Metal Trim Ring, Specify Color
2
PRR6=Rimless Trim Ring for Flush Mount
2
LGSKT6IP66=IP66 Gasket Kit
DT6=Deco Trim
2
Bar Hangers
HB26=C-channel Bar Hanger, 26” Long, Pair
HB50=C-channel Bar Hanger, 50” Long, Pair
RMB22=Wood Joist Bar Hanger, 22” Long, Pair
Transformers
H347=347 to 120V Step Down Transformer, 75VA
H347200=347 to 120V Step Down Transformer, 200VA
Connected Lighting Systems
PORLWTPD1=LumaWatt Pro wireless sensor kit (0-10V only) field installed
15
TMSWPD1=WaveLinx tilemount daylight sensor (includes control module,
sensor, cable and tile mount) field installed
15
Notes:
1 Nominal Lumens will vary depending on selected
color, driver and reflector finish.
2 Order trim with polymer trim ring (Consult
specification sheet for color ordering information
and options).
3 Not available with Chicago Plenum.
4 ULus listed only
5 Beam angles are nominal with LI finish trims.
6 Only available with Narrow and Medium Spun
Aluminum trims. Required for use with all IEMBOD,
IEM7, and IEM14 housings. Requires above ceiling
access with wide beam trim.
7 Only available with Matte White and Matte
Black Finishes.
8 Available only on CS distributions.
9 Not available on PS, CS or BA distributions.
10 Product is marked spacing and must be installed
with the following minimum spacing.
- Center to center of adjacent luminaires: 36”
- Center of luminaire to side of building member: 18”
- Minimum overhead: 1/2”
- Not available with CS or PS trims
11 PS available in self-flanged MW finish only.
12 Offered up to 2000 lumens
13 Flange is the same finish as the reflector
14 DMX fixtures default to full on upon loss of
DMX signal.
15 Refer to system specifications for additional
information, features, and benefits. Order either
factory installed option or accessory. Use with
0-10V driver.
16 Non-IC
SAMPLE NUMBER: EU6B10208035
Power Module
Lumen Levels
1
CRI Color
EU6B=6” Universal LED
Module
1020=1000, 1500, 2000 lumens
3050=3000, 4000, 5000 lumens
6070=6000, 7000 lumens
1015IC=1000, 1500 lumen IC rated
80=80 CRI Minimum
90=90 CRI Minimum
97=97 CRI Minimum
80 CRI
27=2700K
30=3000K
35=3500K
40=4000K
50=5000K
90 CRI
24=2400K
27=2700K
30=3000K
35=3500K
40=4000K
50=5000K
97 CRI
27=2700K
30=3000K
Dim 2 Warm
109030D2W=1000 lumen, 90 CRI, Dim 2 Warm, IC rated
159030D2W=1500 lumen, 90 CRI, Dim 2 Warm, IC rated
209030D2W=2000 lumen, 90 CRI, Dim 2 Warm
309030D2W=3000 lumen, 90 CRI, Dim 2 Warm
Tunable white
16
1020W2N902050 =1000, 1500, 2000 lumens, 90 CRI, tunable white 2000K-5000K
1020W2N902765 =1000, 1500, 2000 lumens, 90 CRI, tunable white 2700K-6500K