Use and Care Manual

Not for
Reproduction
24 www.powerboss-equipment.com
Briggs & Stratton Power Products Group, LLC
P.O. Box 702
Milwaukee, Wisconsin, 53201-0702 U.S.A.
Inverter Generator
(800) 743-4115
* Generator per PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2015, Safety and
Performance of Portable Generators.
** Per Briggs & Stratton 628K, Starting Watts represents the momentary electrical current the generator can provide to start
electric motors. Starting Watts does not represent the power required to continuously run electrical loads. Starting Watts is the
maximum current that can momentarily be supplied when starting a motor, multiplied by the generator’s rated voltage.
Specifications
Running Watts*...................................... 1,600 Watts
Starting Watts**...................................... 2,000 Watts
AC Current at 120 Volts ................................ 13.3 Amps
Rated Frequency ....................................... 60 Hertz
Phase............................................. Single Phase
Displacement .................................6.77 cu. in. (111 cc)
Spark Plug Gap........................ 0.023-0.027 in. (0.6-0.7 mm)
Intake Valve Clearance .......0.0031 - 0.0047 in. (0.08 - 0.12 mm) cold
Exhaust Valve Clearance......0.0051 - 0.0067 in. (0.13 - 0.17 mm) cold
Fuel Capacity ................................ 1.0 US gallon (3.7 L)
Oil Capacity...................................13.5 Ounces (0.4 L)
Common Service Parts
Foam Air Cleaner ......................................311388GS
Breather Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311389GS
Resistor Spark Plug .................................NGK CR7HSA
Engine Oil Bottle ................................100005 or 100028
Synthetic Oil Bottle .......................................100074
Fuel Stabilizer ..................................100120 or 100117