Operation Manual

Owners Manual
R
PowerBoss, Inc. A Member of the Hako Group © 2007 PowerBoss
®
CORE 50 Sweeper Scrubber Page 19
PowerBoss
®
The Power of Clean
CLEANING THE
SOLUTION FILTER
DRAINING THE
SOLUTION TANK
HOPPER FILTER
SHAKER BUTTON
The Cleaning solution passes through a filter canister on its
way to the scrub brushes. This filter can be inspected and
cleaned even if the solution tank is full. This filter is located
on the right side of the machine beneath the foot pedal just
inside of the frame rail.
1. Locate the valve on the forward side of the filter canister
(the valve closest to the broom chamber). Turn the valve
ninety degrees (90°) to close.
2. Grasp the filter canister housing and unscrew. Remove
the housing. The element is inside of the housing and
can be removed for cleaning and inspection.
3. Reinstall the element and housing.
4. Open the valve.
A valve to the rear of the solution filter in the right frame rail
may be opened ninety degrees (90°) to drain the solution
tank.
This button is used to activate the filter shakers prior to
dumping or as needed during sweeping operation. It is
located to the left side of the instrument panel.
To shake the filter:
1. Bring the machine to a complete stop.
2. Place the broom switch in the OFF position.
3. Press and hold the filter shaker button for 20 to 30
seconds.
4. Place the broom switch in the ON position and resume
sweeping.
Do not leave the hopper in the RAISE position for an
extended period of time.
SCRUBBING CONTROLS (Continued)
CAUTION