MODEL 45R & 101R RATCHET REPAIR INSTRUCTIONS
Adaptor Plates For Different Flooring Thicknesses
With a 5/32 allen wrench, unscrew the two #10-32 socket
head cap screws from the access plate.
Remove access plate by turning nailer over.
Remove ratchet insert assembly.
Install new ratchet insert assembly as shown below.
Replace access plate. Important: Make sure access plate is
replaced as shown, with indent facing in towards ratchet.
Fasten access plate back to body using a 5/32 allen wrench
and the two socket head cap screws.
Model 45R flooring nailer
without adaptor plates will
nail standard 33/32" T&G
flooring.
Model 45R flooring nailer
fitted with 8-25 adaptor
plate, to nail standard
25/32" T&G flooring.
Model 45R flooring nailer
fitted with 8-26 adaptor
plate, to nail standard 1/2"
T&G flooring.
Model 45R flooring nailer
fitted with 5/8" adaptor
plate, to nail standard 5/8"
T&G flooring.
®
®
®
®