Replacement Part List
4
MODEL 45R & 101R RATCHET REPAIR INSTRUCTIONS
Adaptor Plates For Different Flooring Thicknesses
• With a 5/32 allen wrench, unscrew the two #10-32 socket
head cap screws from the access plate.
• Remove access plate by turning nailer over.
• Remove ratchet insert assembly.
• Install new ratchet insert assembly as shown below.
• Replace access plate. Important: Make sure access plate is
replaced as shown, with indent facing in towards ratchet.
• Fasten access plate back to body using a 5/32 allen wrench
and the two socket head cap screws.
Model 45R flooring nailer
without adaptor plates will
nail standard 33/32" T&G
flooring.
Model 45R flooring nailer
fitted with 8-25 adaptor
plate, to nail standard
25/32" T&G flooring.
Model 45R flooring nailer
fitted with 8-26 adaptor
plate, to nail standard 1/2"
T&G flooring.
Model 45R flooring nailer
fitted with 5/8" adaptor
plate, to nail standard 5/8"
T&G flooring.
®
®
®
®
5