5 U 5 (volt age source) 5 - 6 V 1 A
5 U 15 - 15 (volt age source) 2 x 12 - 15 V 0 - 200 mA
U - Series LIN EAR MOD U LAR DC POWER SUP PLIES
U
nit 8A
Arnhem Road
Newbury. RG14 5RU
Tel: +44 (0) 1635 521858
Fax: +44 (0) 1635 523771
www.powersolve.co.uk
Mod els
Volt age range Current range
Input : 230 / 115 V AC 48 - 62 Hz
Transformer : Split bobbin, potted, safety transformer According to,
VDE0551, EN60742
Test voltage
Input / Output : 4000 Vrms (output case shorted)
Input / Case : 4000 Vrms (output case shorted)
Output / Case : 500 VDC
Output / Output : 500 VDC ( 5 U 15-15)
Input to output
Leakage current : Typical 5 mA
Coupling capacitance : Less than 60 pF
Insulation resistance : 1000 MOhm
Attenuation input spikes : Better than 100 dB
Specifications
Regulation
Load 0 - 100% : 5 mV
Line ± 10% : 5 mV (at 4 W output)
Ripple and noise : 0.5 mV rms, 2 mV pp
(BW=20 MHz)
Temp. coeff., per °C : 0.01%
Output inpedance
up to 100 kHz : 0.5 Ohm
Recovery time
10 - 100% load step : 25 µs
Operating ambient temp. : - 20 to + 50 °C
MTBF : 1.000.000 hrs
Current limited : Foldback Characteristic
Accessories
P500 Eurocard for the 2 U-units
Front panel F 10-3 for P500
Models with a screw terminals for the rail and wall mounting ( including 2 two clamps for 35 mm rail)
5 U 5 B
5 U 15-15 B
The 5 U 15-15 has two isolated, regulated outputs which are independently adjustable from 12 -15 V
(also unequal voltage) It can be used in 4 different configurations.
Two isolated outputs, each : 12-15 V / 0.2 A
Outputs in parallel : 12-15 V / 0.4 A
Outputs in series : 24-30 V / 0.2 A
Outputs in series, dual : 12-15 V / 0.2 A ±
Dimensions and weight Safety EMC
Height : 35 mm Depth : 94 mm EN 60950 EN 61204-3
Width : 58 mm Weight : 0,4 kg EN 61010 EN 61000-6-3 (EN55022B)
EN 61000-6-2