Product Manual

PHCC Pro Series Chemical
Resistant Pumps
Operating Instructions C8050 & C8100
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
p
roperty damage! Retain instructions for future reference.
Description
PHCC Pro Series submersible chemical resistant pumps are rated for continuous
duty. Pumps are strong and dependable, and when used intermittently in a sump
application, extends the life of the pump. PSC motor design saves energy, reduces
operation costs and provides better service. Intended for pumping non-flammable
fluids compatible with pump component materials.
General Safety Instructions
SAVE THESE INSTRUCTIONS.
This manual contains important
SAFETY WARNINGS and OPERATING
INSTRUCTIONS for the C8050 & C8100
pumps. You will need to refer to it
before attempting any installation or
maintenance.
ALWAYS keep these instructions with
the unit so that they will be easily
accessible.
Failure to read and follow these
warnings and instructions could result
in property damage, serious injury, or
death.
Risk of electric
shock. To reduce
this risk, observe the following
precautions.
ALWAYS disconnect the pump from
the power source before servicing or
making adjustments.
NEVER handle the pump or motor
with wet hands or when standing on
a wet or damp surface while the
pump is plugged into the power
source.
MAKE SURE THERE IS A PROPERLY
GROUNDED RECEPTACLE
AVAILABLE. This pump is wired
with a 3-prong grounded plug. To
reduce the risk of electric shock, be
certain that it is only connected to a
properly grounded, 3-prong
receptacle (preferably with ground
fault circuit interrupt). If you have a
2-prong receptacle, have a licensed
electrician replace it with a 3-prong
receptacle according to local codes
and ordinances.
NEVER bypass grounding wires or
remove the ground prong from the
plug.
DO NOT use an extension cord. The
electrical outlet should be within the
length of the pump’s power cord,
and at least 4 feet above the floor
Specifications
C8050 C8100
HP 1/2 1
Motor Type PSC PSC
Voltage 60 Hz 115 VAC 115 VAC
Amps 4.7 11.3
Water Flow (GPM) at Total Feet of Head
5 Ft. 74 90
10 Ft. 64 82
15 Ft. 51 69
20 Ft. 40 61
25 Ft. 27 53
30 Ft. 13 45
35 Ft. -- 37
40 Ft. -- 24
Max Head 36 Ft. 49 Ft.
Max Dia Solids 1/4” 3/8”
Dimensions
C8050 C8100
HP 1/2 1
Pump Discharge 2” 2”
Materials of Construction
Pump Housing 304 SS 304 SS
Impeller 304 SS 304 SS
Motor Casing
304 SS 304 SS
Inlet Screen 304 SS 304 SS
Motor Shaft 304 SS 304 SS
Mech. Seals (2) Carbon/Ceramic/Viton
Fasteners 304 SS 304 SS
Overall Dimensions
Length 9.1” 10.4”
Width 6.3” 7.5”
Height 16.3” 18.1”
Weight (lbs.) 23.0 46.0