Facility Requirements (continued):
Water Plumbing Requirements:
The customer supplied inlet and outlet plumbing must be rated to withstand
temperatures up to 275°F (135°C) at pressures up to 100 psi (6.9 Bar).
The wall-mounted TYTAN units are supplied standard with 1-inch MNPT threaded pipe
connections for the plumbing inlet and outlet. These connections extend from the right
side of the unit, with the inlet near the bottom and the outlet near the top (see figures 1-
2). There is also a ½-inch FNPT threaded pipe connection for the PRV valve on the
right side of the enclosure which must be plumbed to a non-pressurized drain. Special
plumbing connections are available as an option. Refer to your specific unit for any
special connections.
The free-standing TYTAN units are supplied standard with 2-inch MNPT threaded pipe
connections for the plumbing inlet and outlet. These connections extend from the back
of the unit, with the inlet near the bottom and the outlet near the top (see figure 3).
There is also a ½-inch FNPT threaded pipe connection for the PRV valve on the back of
the enclosure, which must be plumbed to a non-pressurized drain. Special plumbing
connections are available as an option. Refer to your specific unit for any special
connections.
Do not reverse the plumbing connections of
this unit. Failure to observe the correct
plumbing orientation will result in high-
temperature conditions and heater failure.
Electrical Requirements:
NOTE: Ensure electrical power fusing and disconnects meet local jurisdictional
requirements. Fuse ratings noted in this document are for reference only.
Ensure external electrical components comply with local requirements before
operating this unit.
Reference the model/ serial number label to identify the electrical power requirements of
this unit (see figure 4). Verify that the incoming electrical service is rated and fused for
the required amperage draw.
Do not exceed the rated voltage. Irreparable
damage to the heating column or control
circuitry may result.
M-45-02 TYTAN Manual
Revision - Date: 01 – 11/16/07