INSTALLATION (Continued):
Plumbing (Continued):
PRV Plumbing Connection:
1) Test fit the drain pipe to insure proper length. The PRV must be connected to a non-
pressurized drain.
2) Support the TYTAN PRV fitting to avoid any damage during tightening.
3) Tighten the connection as required. Take care not to over-tighten.
Wiring:
The wiring of this unit should only be performed by qualified technicians.
Verify that the electrical power supply is shut
off, and any necessary lockout/tagout devices
are properly installed.
Power Connections:
TYTAN units are designed to operate on 4 wire electrical power supplies (3 power
wires, 1 ground wire). All electrical connections should conform to local electrical codes
and/or NFPA 70/79.
There is no pilot hole for incoming power supply conduit. This hole will have to be cut in
the top of the enclosure during installation.
Figure 8: Recommended location for power supply conduit (72kW unit shown)
1) Check the model/serial number on the front of the unit for power requirements.
Do not exceed the rated voltage. Irreparable
damage to the heating column or control
circuitry may result.
M-45-02 TYTAN Manual
Revision - Date: 01 – 11/16/07