Instruction manual

MAINTENANCE:
The Tytan water heater requires only a routine inspection every 6 months to check the
operation of the various operation and safety devices. Many of these devices require
the control system to remain operational during inspection, while others may be
checked while the unit is completely powered down.
Note: Several maintenance tasks can be completed simultaneously while the
cabinet access covers are open and lockout/tagout procedures are in place.
The maintenance procedures for this unit must be performed by qualified technicians.
Normal maintenance of TYTAN DI Water Heaters consists of the following:
1) Disinfect the water heater along with the rest of the plumbing system on a regular
basis if continuous sanitizing such as ozone injection is not employed.
2) Inspect the temperature sensors every 24 months, replace as needed.
3) Replace the heater control relays and fan after approximately 24-30 months of use.
Actual life expectancy varies with application conditions such as hours of operation;
control tuning parameters, applied voltage and amperage.
4) The Solid State Relay fan should be replaced and the heat sink is to be cleaned
every 24 months.
M-45-02 TYTAN Manual
Revision - Date: 01 – 11/16/07
43