Instruction manual

SYSTEM SPECIFICATIONS:
Product TYTAN inline titanium water heater
Standards UL, cUL standard
CE, SEMI S3 optional (-SC)
Available Wattage Range
12kW – 144kW
Refer to model number label for the wattage of any specific unit
Available Voltages
208V – 600V, 50/60Hz, 3 phase standard
(Some voltages available in single phase or with special construction,
consult factory for details)
Cabinet dimensions: Width Depth Height Weight
12kW – 48kW 28.5-in (75 cm) 13.5-in (34 cm) 36-in (91 cm) 145 lbs. (66 kg)
72kW 37.5-in (95 cm) 13.5-in (34 cm) 36-in (91 cm) 230 lbs. (104 kg)
96kW – 144kW 28-in (71 cm) 17-in (43 cm) 63-in (160 cm) 300 lbs. (136 kg)
Wetted surfaces:
Heating elements CP2 titanium standard, (316SS optional [-S option])
Columns and plumbing CP2 titanium standard, (316SS optional [-S option])
PRV Valve PVDF
Operating temperatures:
Process inlet
Process outlet Up to 194°F (90°C), depending upon operating conditions
Temperature accuracy +/- 1°F, depending upon operating conditions
Ambient air temperature 86°F (30°C) maximum
Water pressure range
Minimum 10 psi (69 kPa, 0.69 bar)
Maximum 100 psi (690 kPa, 6.9 bar)
Minimum water flow rate:
12kW - 24kW 0.5 gpm (2 lpm)
36kW – 48kW 1.0 gpm (4 lpm)
72 kW 1.5 gpm (6 lpm)
96kW 2.0 gpm (8 lpm)
120kW 2.5 gpm (10 lpm)
144kW 3.0 gpm (12 lpm)
Standard Safety Devices: EMO Pushbutton
Pressure Relief Valve (PRV), connected to inlet manifold
Electrically grounded heating chamber construction
Ground Fault Protection (GFP)
Safety Limit Control (SLC)
Bimetallic heater over temperature sensor(s)
Heater outlet overtemperature alarm
Solid state relay (SSR) overheat bimetallic sensor
Sensor failure detection
Control circuit fuse protection
Table 3: TYTAN Specifications
M-45-02 TYTAN Manual
Revision - Date: 01 – 11/16/07
6