The Solar Adjustment feature allows the grower to adjust the cooling temperature setpoint up or down depending on how
intense the solar level is. The solar level is monitore4d by the K-Lux sensor if used. The solar level can also be monitored by
a PAR or Pyranometer sensor if connected to the Procom.
Setpoint Ramp
(30) Minutes/Deg
This is the ramp time of the heating system. Enter the desired time that it will take the system to implement a
change in the heating setting. The Procom will use this time when changing modes (Day, Midday, Evening, and
Night).
Link Heating 1
To (Output Selection)
(IF LINKED)
Heating 1 (Max) 0
If Output (Selection) ON
You may use this setting to link a Heating selection to any particular output. This also includes vents or shade
systems. When this feature is used, the Heating stage(s) will either turn off completely (0 selection), or turn off
partially (maximum stage selection) when a particular output, shade, or vent is active.