Operating instructions

16
SET FOGGING
The SET FOGGING mode is used to set the temperature and humidity differentials and the system timing for the
fogging output. The grower can also select if the fogging system should be maintained on or pulsed in this mode.
1. Enter the SET FOGGING mode.
2. Use the PRIOR-NEXT switch to advance to the desired item to set.
3. Use the VALUE switch to toggle between desired choices that the system has internally provided.
Fog 1 Diff.
(2)
o
Temp 2% RH
Set the desired differentials for the temperature and the humidity settings for the fogging stage. The differential is
the amount of temperature decrease or humidity increase that the sensor must see before turning off the fogging
stage.
Fog 1 Timing
(2 Sec.)
Set the desired time delay here. The time delay will be active on both energizing and de-energizing stages.
Fog 1
(Maintained)
Fogging output may be commanded in two way, maintained or pulse. Maintained will turn on the output till the
humidity increases into the controlling band. Pulsed will allow the grower to enter the run and wait time to more
slowly increase the humidity level.
(IF PULSED SELECTED)
Fog 1 On
(2 Sec.)
Select the desired running time for the fogging system.
Fog 1 Off
(2 Sec.)
Select the desired waiting time for the fogging system.