Operating instructions

5
RUN REPORTS
The RUN REPORTS mode allows the grower to run selected reports on the sensor history.
1. Enter the RUN REPORTS mode.
2. Use the PRIOR-NEXT switch to advance to the desired report.
3. Continue to use the PRIOR-NEXT switch to advance and view reports.
Display Report
(Inside)
Select the desired report for display.
CALIBRATE
The CALIBRATE mode is used in order to calibrate all of the sensor readings. It is also used to calibrate the vent
and shade positions in the event that they have been moved manually and do not match the GROWMASTER
display as to the percentage opening. Calibration always should be done with a good thermostat or humidity
indicator, and when conditions have been calm for a period of time. Late afternoon or early morning is best,
without solar influence.
1. Enter the CALIBRATE mode.
2. Use the PRIOR-NEXT switch to advance to the desired item to calibrate.
3. Use the VALUE switch to increase or decrease the display reading.
Calibrate:
Air Temp 1 80
o
F
Set the desired value. The calibration procedure should be done with a reliable thermometer, out of direct solar
influence when calibrating temperatures. Use a wet and dry bulb to calculate humidity.
You may also calibrate any ventilation or shade position in this mode. Advance to the desired vent or shade
position in the CALIBRATE mode, and enter the actual position of the vent or shade system. The Procom will then
move the vent or shade to the correct position.
Calibrate:
Vent 1 50%