5,000W/240V WALL / CEILING MOUNTED GARAGE HEATER WITH ELECTRONIC CONTROLLER AND REMOTE OWNER’S MANUAL Model: PH-950NR IMPORTANT INSTRUCTIONS READ & SAVE PET OWNERS WARNING: The health of some small pets including birds are extremely sensitive to the fumes produced during the first-time use of many appliances. These fumes are not harmful to humans but we recommended that you do not use your heater around birds and small pets during its initial use until the manufacturing corrosion coatings burn off.
TABLE OF CONTENTS Important Instructions………………………………………. 3-4 Installation Instructions…………………………….…………5-7 Specifications and Wiring Diagram ………………………. 8 Parts of the heater……………………….…………..……. 9 Operating Instructions……………………….………....…… 10-12 Maintenance and Cleaning………………………………. 12 Troubleshooting…………………………………………….
IMPORTANT INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS HEATER NOTE: There may be a trace of smoke or odor when unit is first operated. Don’t be alarmed. This indicates that a drop of oil fell on the heating coil during the manufacturing process. It will quickly evaporate and should not re-occur. Make sure that the room in which the appliance is located is well ventilated during this operation. It is normal for the appliance to emit small cracking sounds when you turn it on for the first time.
adjacent vertical surfaces or walls. Keep at least 4.5 inches (11.5cm) from the back wall (with or without using the wall hanging mounting bracket). 9) Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater. 10) To prevent a possible fire, do not block air intakes or exhaust in any manner. 11) A heater has hot and arcing or sparking parts inside.
INSTALLATION INSTRUCTIONS WARNING: All wiring must be installed by a certified electrician according to the electrical safety. The ceiling heater must be grounded in accordance with all national and local building codes. WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater. All Wiring procedures and connections shall be in accordance with the national and local codes having jurisdiction.
3. Keep at least 4.5 inches (11.5 cm) from the back wall (with or without using the wall hanging mounting bracket). 4. Mark the drill-hole positions in the wall or ceiling for the mounting bracket. 5. Drill the required holes with diameter fit for the anchor provided for positioning the mounting bracket. 6. Insert the anchors. 7. Attach the mounting bracket to the wall or ceiling and secure with mounting screws. WALL MOUNT CEILING MOUNT 8.
10. Loosen the screw to remove the wiring compartment/connection cover in the rear of the heater. 11. Run the electrical power supply cable in flexible conduit and connect to the wiring compartment via the knock-out at back side of the unit. 12. Make the connections properly with connectors which are suitable for the conductor size, including grounding wiring. And after making the connections, arrange the pigtail leads of unit and power supply wires in the wiring compartment.
SPECIFICATIONS 5,000W/240V WALL / CEILING MOUNTED GARAGE HEATER WITH ELECTRONIC CONTROLLER AND REMOTE Model: PH-950NR Volt: 240 V Watts: 5000 W Frequency: 60 Hz Recommended Heating Capacity: 1.25 watts / ft³ (0.
PARTS OF THE HEATER A C B D E F G A. B. C. D. E. F. H I J K Upper enclosure Tilt adjustable knob Front exhaust grill Louver for air direction Control panel Alarm LED G. H. I. J. K. L Power indicator Timer indicator Low indicator High indicator Inside/Wall thermostat switch L.
OPERATING INSTRUCTIONS WARNING - The heater must be properly installed before it is used. HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH: Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70. A circuit breaker must be installed and serviced only by qualified electrical personnel. Always use a properly rated voltage sensing device to confirm power is off. The Select switch on the heater is only for function selection.
TURNING THE HEATER ON To turn the heater ON, press the ON/OFF rock switch to ON position, the power indicator will turn on and display the room temperature. The factory setting temperature is 70℉, if you set the thermostat switch to Inside Thermostat, and the room temperature is lower or equal to 68℉, the heater will turn to High mode and will turn off when the room temperature is higher or equal to 72℉.
To turn off the heater, switch off the circuit breaker. The circuit breaker serves as the power disconnection means. This heater includes a visual alarm to warn that parts of the heater are getting excessively hot. If the alarm flashes, immediately turn the heater OFF and inspect for any objects, on or adjacent to the heater that may cause high temperatures. DO NOT OPERATE THE HEATER WITH THE ALARM FLASHING.
TROUBLESHOOTING If your heater fails to operate, please follow these procedures: This heater is intended to be a ceiling-mounted heater. It has a thermal cut-off protection. If the thermal cut-off protection trips, then, switch off the power. Switch off the circuit breaker.The unit should reset automatically after 10 minutes. If the thermal cut-off protection trips again, consult a certified electrician to determine the reason for overheating.
PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF. DOING SO COULD CAUSE DAMAGE OR PERSONAL INJURY.