Installation Guide

13.
Troubleshooting
Solution
1. Check circuit fuses or breakers.
2. Check line wire connections to the fan and switch wire connections in the switch housing.
CAUTION: Make sure main power is off.
1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade bracket to the motor hub is tight.
3. Make sure wire nut connections are not rubbing against each other or the interior wall of the switch housing.
CAUTION: Make sure main power is off.
4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan disappear during this time.
5. If using an optional light kit, make sure the screws securing the glassware are tight. Check that light bulb is also secure.
6. Some fan motors are sensitive to signals from solid-state variable speed controls. If you have installed this type of control,
choose and install another type of control.
7. Make sure the upper canopy is a short distance from the ceiling. It should not touch the ceiling.
1. Do not connect the fan with wall mounted variable speed control (s).
2. Make sure the dip switches are set correctly.
1. This unit is equipped with a wattage limiting device. Lamping in excess of 70 watts will disable your ceiling fan's light kit. To
reset your light kit you must turn the power off and re lamp, keeping the wattage under 70 watts. Restore power to your ceiling
fan and continue normal operation.
Problem
Fan will not start.
Fan sounds noisy.
Remote control
malfunction.
Lights shut off and
will not come back
on.