Operation Manual

Set the water softener
The dishwasher is equipped with a water
softener designed to remove minerals and
salts from the water supply, which would
have a detrimental or adverse effect on the
operation of the appliance.
The higher the content of these minerals and
salts, the harder your water is. Water hard-
ness is measured in equivalent scales, Ger-
man degrees (dH°), French degrees (°TH)
and mmol/l (millimol per litre - international
unit for the hardness of water).
The softener should be adjusted according
to the hardness of the water in your area.
Your local Water Authority can advise you on
the hardness of the water in your area.
The water softener must be set in two
ways: manually, using the water hard-
ness dial and electronically.
Water hardness Adjusting the water hardness setting Use of
salt
°dH °TH mmol/l manually electronically
51 - 70 91 - 125 9,1 - 12,5 2 level 10 yes
43 - 50 76 - 90 7,6 - 9,0 2 level 9 yes
37 - 42 65 - 75 6,5 - 7,5 2 level 8 yes
29 - 36 51 - 64 5,1 - 6,4 2 level 7 yes
23 - 28 40 - 50 4,0 - 5,0 2 level 6 yes
19 - 22 33 - 39 3,3 - 3,9 2 level 5 yes
15 - 18 26 - 32 2,6 - 3,2 1 level 4 yes
11 - 14 19 - 25 1,9 - 2,5 1 level 3 yes
4 - 10 7 - 18 0,7 - 1,8 1 level 2 yes
< 4 < 7 < 0,7 1 level 1 no
Setting manually
The dishwasher is factory set at position
2.
1. Open the dishwasher door.
2. Remove the lower basket from the dish-
washer.
3. Turn the water hardness dial to position
1 or 2 (see chart).
4. Replace the lower basket.
Setting electronically
The dishwasher is factory set at level 5.
1. Press the On/Off button. The dishwasher
must be in setting mode.
2. Simultaneously press and hold function
buttons B and C, until the lights of func-
tion buttons A, B and C start flashing.
3. Press function button A, the lights of
function buttons B and C go off while the
light of function button A continues to
flash, at the same the End indicator light
starts to flash.
The current level is indicated by the num-
ber of flashes of the End indicator light.
Examples:
5 flashes, pause, 5 flashes, pause, etc. =
level 5
6 flashes, pause, 6 flashes, pause, etc. =
level 6
4. To change the level, press function but-
ton A. Each time the button is pressed
the level changes. (For the selection of the
new level see the chart).
Examples: If the current level is 5, by
pressing function button A once, level 6
is selected. if the current level is 10, by
progress 73