7. Fit the correctly rated fuse.
If the charger is used in a Permanent/Hard Wired application and the vehicle will not
be used for some time, it is best to leave the charger connected to mains power (turned
‘On’) so that it can maintain the battery fully charged.
Ensure any modification to the 240V mains lead is carried out by a qualified person and
that connection to supply mains is in accordance with National wiring rules.
BATTERY CHEMISTRY SELECTION
The Multi-Chem function allows you to set the charging profile to suit each battery’s
chemistry type (GEL, AGM, WET and Calcium). This ensures correct and thorough
charging and maximizes battery performance and battery life.
1. Press the Mode button; all the lights will come on. Wait for the lights to turn off.
2. Press the Mode button repeatedly until the correct battery type is selected.
POWER SUPPLY (CONSTANT VOLTAGE OF 13.8 VOLTS)
This sets the charger in power supply mode giving a constant voltage of 13.8VDC.
This mode is best used where appliances are drawing power from the battery, for
example like a Fridge. Although the charger is designed to work with a battery
connected, it can also work without a battery.
GEL (MAX VOLTAGE OF 14.1 VOLTS)
This charge mode is designed for GEL batteries and has a maximum charge voltage
of 14.1V. Note that some GEL batteries require a higher charge voltage such as 14.4V.
The AGM mode can be used if this is required.
AGM (MAX VOLTAGE OF 14.4 VOLTS)
This charge mode is designed for AGM batteries and has a maximum charge voltage
of 14.4V.
WET (BULK AND ABSORPTION 14.7 VOLTS, RECONDITION UP TO 16 VOLTS)
This charge mode is designed for WET batteries and has a maximum charge voltage
of 14.7V during Bulk and Absorption stages and 16.0V during the Recondition stage.
Inline fuse Ring terminal
FOR LEAD ACID CELL BATTERIES