USER MANUAL FASTTRAKS 150TX2

Chapter 2: Getting Started
37
FastBuild (tm) Utility 2.xx (c) 2002-2005 Promise Technology, Inc.
[ Rebuild Array Menu ]
Array No RAID Mode Total Drv Status
Array 2 Mirror 2 Critical
Stripe Block: Not Available Gigabyte Boundary: ON
[ Select Drive for Rebuild ]
Channel:ID Drive Model Capacity (MB)
1 : SEAGATE S380023AS 80024
[ Keys Available ]
[] Up [] Down [ESC] Exit [Enter] Select
11. Under Select Drive for Rebuild, highlight the replacement drive.
12. Press Enter and confirm that the data will be copied on to the selected
drive. All data on the replacement drive will be written over with mirrored
information from the array drive. A progress bar will appear as below.
Please Wait While Duplicating The Image
10%
Complete
13. Once the rebuild process is complete, reboot the system.