VTRAK M-CLASS Product Manual

VTrak M-Class Product Manual
176
4. Press Ctrl-A to save your settings.
Enclosure Management
Enclosure Management includes information, status, settings and location. To
access Enclosure Management:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
To access FPU VPD information (vital product data on field replaceable units),
highlight FPU VPD Information and press Enter.
To access the current status of the power supplies, blowers, temperature or
voltage sensors, highlight the item you want and press Enter.
Enclosure Status
Enclosure Management
The current status of the power supplies, blowers, temperature or voltage
sensors:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight power supplies, blowers, temperature or voltage sensors and press
Enter.
Power Supply Units
This screen displays the operational and fan status of VTrak’s two power
supplies.
PSU (power supply unit) status – Should show Power On and Functional
Fan Status – Should show Functional
Healthy Threshold – Minimum acceptable fan speed
Current Fan Speed – Should be greater than the Healthy Threshold value
If any status differs from those listed above or the fan speed is below the Healthy
Threshold value, there is a fan/power supply malfunction. See “Chapter 6:
Maintenance” on page 215.
Blowers
This screen displays the status and speed of VTrak’s blowers. There are two
blowers in each cooling unit. 500-series VTraks have two cooling units. 300- and
200-series VTraks have one cooling unit.
Blower status should be Functional
Healthy Threshold – Minimum acceptable fan speed
Current Speed – Should be greater than the Healthy Threshold value