User manual

Modular Matrix Switcher 8x8 (with Audio)
PTN Electronics Limited 22 www.PTN-electronics.com
Example: “USER/I/7:0623%;” to set the input 7 to support YPbPr signal, the card is
plugged in the second input slot of the matrix.
Note: If there is any empty input card or output card, and send the command ALL#.It
will be taken and the result is as 1->1, 2->2, 3->3, but actually there is no input/output
signal at this card.
4.4. TCP/IP Control (Optional)
4.4.1. Control Modes
TCP/IP default settings: IP is 192.168.0.178, Gateway is 192.168.0.1, and Serial Port is
4001. IP & Gateway can be changed as you need, Serial Port cannot be changed.
Controlled by Single PC
Connect a computer to the TP port of the MMX88A, and set its IP address and gateway
to the same IP section as the default IP of the MMX88A (192.168.0.178).
Controlled by PC(s) in LAN
The MMX88A can be connected with a router to make up a LAN with the PC(s), this
make it able to be controlled in a LAN. When control, just make sure the MMX88As IP
section is the same with the router. Please connect as the following figure for LAN
control.
Same IP as the
switcher