Instruction manual

Page 26
GigE Series Camera Serial Commands
TM-1327GE Software
Table 5. 18 Bytes Status Report
Byte 1, 2 MGA Gain Control (H’0000 - H’00FF)
Byte 3, 4 VTOP VTOP (H’0080 - H’00C0)
Byte 5, 6 VBTM VBOTTOM (H’0078 - H’00FF)
Byte 7,8 Reserved
Byte 9 Function Flag 0
Bit 7 output pixel order 1
“00”=<-- “10”=<--
“01”=<--
Bit 6 output pixel order 0
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Scan Mode
Full/Partial Scan
Byte 10 Function Flag 1
Bit 7 ShutterMode2 “000”=Manual Shutter
“001”=Async Shutter
“010”=Async Direct Shutter
“011”=Direct Shutter
Bit 6 ShutterMode1
Bit 5 ShutterMode0
Bit 4 Output Data Depth 0=8 bit 0=8bit; 1=10bit
Bit 3
Bit 2
Bit 1
Bit 0
Byte 11 Function Flag 2
Bit 7 LUTSIGN 0=Positive LUT; 1=Negative
LUT
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2 LUTTABLE2 000”=Linear LUT
“001”=Gamma.45 LUT
“010”=Two Knee Table
Bit 1 LUTTABLE1
Bit 0 LUTTABLE0
Byte 12 Function Flag 3