TROUBLE SHOOTING
CONDITION CAUSE CORRECTIVE
Compressor won’t
start
1Loose electrical connection
2Motor overheated
1Check wiring connection
2Press reset button or wait for
automatic reset
Low pressure
1Malfunction in valves
2Loose tube of fittings
3Restricted air filter
4Defective check valve
1Check inlet and exhaust valves
2Tighten fittings
3Clean or replace filter
4Replace check valve
Pressure relief valve
releasing
1Defect pressure switch or
improper adjustment
2Defective pressure relief valve
1Check for proper adjustment and
if problem persists replace
pressure switch
2Replace valve
Excessive dust
formation or
appearance of water
1Restricted air intake filter
2Worn valves
3Worn piston rings
4High ambient temperature
and / or humidity
5Over usage of this compressor
1Clean or replace filter
2Replace valve assembly
3Replace piston ring
4Install a moisture separator
and/or dryer
5Check for air leakage. If no leaks
are found, bigger compressor
is needed.
Water in air receiver
tank
1Condensation in the air
receiver
1Drain daily or install an automatic
drain
Excessive noise
1Loose valves
2Loose piping
3Unit not installed level
4Carbon or foreign material on
piston
5Worn bearings
1Inspect valve for damage
2 : Tighten as required
3Ensure that unit is mounted level
4Clean piston
Check cylinder walls for scoring
5Replace bearings