Compressor over
heated
1Undersized unit for air
requirements
2Compressor location
3Air leaks in the system
4Restricted air filter
5Worn, damage, or carbon
build up on valve
6Carbon build up at after - cooler
tube or check valve
1Contact PUMA compressor
distributor
2See installation section
3Fix leaks
4Clean or replace filter
5Clean or replace valves
6Clean or replace as needed
Pressure switch does
not unload or leak air
when unit is not
operating
1Pressure switch unloading
may be dirty or faulty
2Check valve may be dirty or faulty
1Clean, repair or replace
pressure switch
2Clean, repair or replace check
valve
Air leaks at check
valve
1Defective or dirty check valve 1A defective check valve results in
a constant air leak when there is
pressure in the tank, remove
and clean or replace valve.
Air leaks in air tank or
at tank welds
1Defective air tank 1Air tank must be replaced,
do not repair the leak.