Product Manual
11
Compressor over
heated
1:Undersized unit for air
requirements
2:Compressor location
3:Air leaks in the system
4:Restricted air filter
5:Worn, damage, or carbon
build up on valve
6:Carbon build up at after - cooler
tube or check valve
1:Contact PUMA compressor
distributor
2:See installation section
3:Fix leaks
4:Clean or replace filter
5:Clean or replace valves
6:Clean or replace as needed
Pressure switch does
not unload or leak air
when unit is not
operating
1:Pressure switch unloading
may be dirty or faulty
2:Check valve may be dirty or faulty
1:Clean, repair or replace
pressure switch
2:Clean, repair or replace check
valve
Air leaks at check
valve
1:Defective or dirty check valve 1:A defective check valve results in
a constant air leak when there is
pressure in the tank, remove
and clean or replace valve.
Air leaks in air tank or
at tank welds
1:Defective air tank 1:Air tank must be replaced,
do not repair the leak.