5.2ELECTRICAL
Please ensure that the air compressor is electrically connected in a safe and correct manner.
Any electrical work should be carried out by an electrician and installed in a way which meets
all applicable codes and regulations.
Failure to connect the air compressor correctly to your buildings electrical services may result
in serious personal injury or damage to the equipment.
Please note that under normal conditions, the air compressor will operate intermittently.
Should it be necessary to service, ensure the power source has been shut down to prevent
personal injury or damage to the unit.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or
a qualified person in order to avoid a hazard.
5-2-1MOTOR
Wiring must be done in a manner that full voltage nameplate ±10% is available at the motor
terminals during startup. Use of an incorrect power source will result in premature motor
failure and is not covered by PUMA compressor or motor manufacture’s warranty.
5-2-2THERMAL RELAY
Ensure that all guards and shrouds are in place before pressing reset switch to restart the
motor. If the motor shuts down because of overload, wait 10-15 minutes so the motor can
cool down, then press the reset switch to restart motor. The reset switch button is located on
the motor housing.
5-2-3PRESSURE SWITCH
The pressure switch acts as a pilot device activating the motor. The pressure switch cut in/cut
out has been preset at the factory, do not tamper with the settings. Never bypass or remove
this switch, as serious damage to equipment or personal injury could result from improper
pressure setting. Consult your local distributor or service center if the switch malfunction.