Product Manual
9
8:MAINTENANCE CHECK LIST
Before doing any maintenance or adjustments to your air compressor, the following safety
precautions should be taken.
A
:
:DISCONNECT ELECTRICAL POWER.
B:MAKE SURE NO AIR PRESSURE IN AIR RECEIVER.
8-1
:
:Daily checklist
8-1-2:Drain condensation from air receiver tank.
8-1-3:Check for any unusual noise or vibration.
8-1-4:Be sure all nuts and bolts are tight.
8-2
:
:Weekly checklist
8-2-1:Clean air filter, replace if necessary.
8-3
:
:Quarterly or 300 hour checklist
8-3-1
:
:Change filter element.
8-3-2
:
:Check pressure relief valve.
8-3-3
:
:Check pressure switch to ensure unloads whenever motor shuts down.
8-3-4
:
:Clean and blow dust or dirt off pump fins and motor.
8-3-5:Inspect air system for leaks by applying soapy water to all joints. Fix it
if leakages are observed.
9:STORAGE:WHEN YOU HAVE FINISHED USING THE AIR COMPRESSOR:
9-1
:
:Set the switch to OFF and unplug the cord.
9-2:
::
:Be sure to drain the water from the air tank.
9-3
:
:Protect the electrical cord and air hose from damage.
9-4
:
:Store the air compressor in a clean and dry location.