- Digital Peripheral Solutions Security Camera - IP Server User Manual

QT19D328SC Users Manual
17
Blink the video from the camera will still be recorded.
3.3.3 Alarm Set
a). Terminal Port
b).
: 1,2, 3, 4 represent the 4 outer I/O alarm input ports.
Alarm
c). I
Two choices are On or Off. Users have the option to turn on /off alarm for each channel
nput Mode
d).
: Two choices are Close/Open, closed circuit and open circuit. Users have the option to Normally Closed or
Normally Open alarms.
Record Delay
e).
: Record delay is the length of time the DVR keeps the file open once the alarm has stopped before starting a
new file with the next detected alarm event. The options are from 10 to 300 sec.
Output Delay
f).
: Under the alarm recording mode, the system is communicating the alarm output signal with the alarm output
end point automatically after moving the testing signal has received the alarm signal from the I/O. Delay the alarm output
means delaying the continuous time of the alarms output signal.
I/O alarm output
g).
: Two choices are On or Off. This option opens or closes the option to send a signal from the DVR to
another alarm device.
Motion alarm output
the same as the above except for built-in motion detection instead of an external alarm sensor.
3.3.4 Work Set
The Work Set Menu includes scheduling recording for each channel and the option to set up the senitive area for each channel for
motion detection.
The specific operation of each function is given below:
Alarm/Timing Setup
Port Alarm Mode Timing Setup
1 On Close Record Delay: 030
2 On Open Output Delay: 010
3 Off Close Buzzer Duration: 000
4 Off Close I/O Alarm Out: On
Motion Alarm Out: On
Record Setup
Channel Schedule Area Set
1 Setup Setup
2 Setup Setup
3 Setup Setup
4 Setup Setup
Return