Owner's manual

1 SCOPE
1.1 Scope.
This specification establishes the detail requirements for hybrid, hermetically sealed, crystal
oscillators for use in space flight missions.
1.2 Part number.
The part number shall be as specified in Table I herein.
2 APPLICABLE DOCUMENTS
2.1 Specifications and standards.
Unless otherwise specified, the following documents shall be
applicable to this specification to the extent specified herein.
SPECIFICATIONS
401-0298-001
Hybrid Crystal Oscillators, Class S, General Specification For
3 REQUIREMENTS
3.1 General requirements.
The individual item requirements shall be as specified in the General
Specification with the exceptions, modifications, and additions specified herein.
3.2 Approved manufacturer.
Hybrid crystal oscillators shall be supplied from the manufacturer specified
in paragraph 7.1 herein.
3.3 Design and construction.
3.3.1. Outline dimensions and terminal connections.
The outline dimensions and terminal connections shall
be as shown in Figure 1 herein.
3.3.2. Package body and lead finish.
The package body and lead finish shall be gold in accordance with
MIL-PRF-38534.
3.3.3. Active Devices.
The microcircuit used in this part shall use CMOS technology and shall be from a
wafer proven to be radiation tolerant to 100 kRad (Si) total ionizing dose.
3.3.3.1 CMOS microcircuit usage.
For frequencies below 12 MHZ the CMOS output microcircuit shall be
54AC191, see DSCC SMD 5962-89749. For frequencies greater than or equal to 12 MHZ, the
CMOS microcircuit shall be 54AC00, see DSCC SMD 5962-87549. These microcircuits are specified
to be single event latchup free for LET up to 93 MeV-cm
2
/mg. For output frequencies up to 70 MHz,
the manufacturer shall be ST Microelectronics Corporation. For output frequencies greater 70 MHZ,
the manufacturer shall be National Semiconductor Corporation.
3.4 Performance requirements.
3.4.1. Maximum ratings.
The maximum ratings shall be as specified in Table II herein.
3.4.2. Electrical performance characteristics and limits.
The electrical performance requirements and limits
shall be in accordance with Table III herein.
3.4.3. Delta limits.
Except for frequency aging (refer to Table III), delta limits shall be in accordance with the
General Specification.
3.4.4. Total dose radiation limits.
Hybrid crystal oscillators supplied in accordance with this specification
shall be capable of meeting the performance requirements after being exposed to 100 krad total dose
radiation levels.
THIS DOCUMENT IS CONSIDERED PROPRIETARY TO Q-TECH CORPORATION
DO NOT COPY OR DISTRIBUTE WITHOUT Q-TECH CORPORATION APPROVAL
Q-Tech Corporation
10150 W. Jefferson Blvd.
Culver City, CA. 90232
Specification number: QT625L rev. F
Sheet 2 of 5