Reference Guide

Chapter 4 SCSI Commands
MODE SELECT (6) / (10) Command (15h / 55h)
DLT-S4 Interface Reference Guide 104
Mode Parameter Block
Descriptor
4
Figure 56 and table 65 illustrate and describe the fields that make up the
MODE SELECT command’s Mode Parameter Block Descriptor.
Figure 56 MODE SELECT
Mode Parameter Block
Descriptor — Data Format
Table 65 MODE SELECT
Mode Parameter Block
Descriptor — Field Descriptions
Bit
Byte
7 6 5 4 3 2 1 0
0 Density Code
1 — 3
(MSB)
Number of Blocks
(LSB)
4 Reserved
5 — 7
(MSB)
Block Length
(LSB)
Field Description
Density Code This field must contain one of the Density Code values listed below:
Density
Code Description
00h Use default density
49h 190,000 bpi, 56 logical tracks, serial cartridge tape
160 GB / 320 GB (Super DLTtape I)
1
4Ah 233,000 bpi, 40 logical tracks, serial cartridge tape,
300 GB / 600 GB (Super DLTtape II)
4Bh 256,000 bpi, 80 logical tracks, serial cartridge tape,
800 GB / 1600 GB (DLTtape S4)