Reference Guide

Chapter 4 SCSI Commands
MODE SELECT (6) / (10) Command (15h / 55h)
DLT-S4 Interface Reference Guide 151
table 87. Note that the parameter name may be in upper or lower case.
The drive saves the savable parameters during resets and power cycles.
Table 87 EEPROM Mode
Page — Parameter
Descriptions
Parameter Data Type Default
Length
(Bytes) Usage
VendorID ASCII QUANTUM 8 Vendor Identification field in
INQUIRY data.
CacheTMs Binary 0 1 When set, the drive always treats a
WRITE
FILEMARKS
command that writes a single
filemark and is not preceded by another
WRITE FILEMARKS command as if the Immed
bit was set to 1.
DefaultCompON Binary 1 1 When set to 0, indicates that compression is
defaulted OFF at power-on/reset.
When set to 1, indicates that compression is
defaulted ON at power-on/reset.
DefFixedBlkLen Decimal 0 4 Default fixed block size. Minimum value of
this field is 0, maximum value is 16,777,215.
DefSEW Binary 1 1 Default Synchronize at Early Warning
parameter.
DisDeferClnRpt Binary 0 1 When set to 1, the drive sends a cleaning
report over the library port as soon as the
cleaning light illuminates. When set to 0, the
drive sends the report only at unload.
DisUnbufMode Binary 0 1 When set to 1, the drive completely disables
unbuffered mode; it ignores the
MODE
SELECT
buffered mode selection to turn off
buffered mode. When set to 0, buffered mode
can be enabled or disabled.
EnaCleanLib Binary 1 1 When set to 1, the drive reports cleaning
status using the library tape drive interface.
When set to 0, this functionality is disabled.