MODE SELECT (6) / (10) Command (15h / 55h)
DLT-S4 Interface Reference Guide 156
Changeable Parameters
Within
MODE SELECT 4
Table 88 lists the MODE SELECT command’s changeable parameters and
their default, minimum, and maximum values. Descriptions of the
various parameters are provided in the discussions of the different
MODE
SELECT
mode pages.
Table 88 Changeable Mode
Parameters Within MODE
SELECT
Note: Parameter rounding is supported for all parameters except the
Block Descriptor Length parameter.
Page: Parameter Default Minimum Maximum
Header: Buffered Mode, Device Specific Byte 1 0 1
Block Descriptor Length 08h 00h 08h
Block Descriptor: Block Length 0 0 FFFFFCh
1
Read / Write Error Recovery (01h): PER bit 0 0 1
Control Mode (0Ah): Report Log Exception Condition 0 0 1
Control Mode (0Ah): Autoload Mode 0 0 2
Data Compression (0Fh): Data Compression Enable 1 0 1
Disconnect / Reconnect (02h): Maximum Burst Size 0080h 0000h FFFFh
Device Configuration (10h): Write Delay Time 64h 64h 1964h
Device Configuration (10h): Synchronize at Early Warning 1 0 1
Device Configuration (10h): Select Data Compression Algorithm 1 0 1
TapeAlert (1Ch): DExcpt 1 0 1
TapeAlert (1Ch): Perf 0 0 1
TapeAlert (1Ch): Test 0 0 1
TapeAlert (1Ch): MRIE 3 0 6
TapeAlert (1Ch): Test Flag 0 0
1. All values between the minimum and maximum must be an even multiple of 4.