User`s guide

Drive Cleaning Tasks
108 SL500 User’s Guide July 2008 Revision: KA 96116
6. Place the cartridges into the empty magazine cells, making sure that the VOLID label
is visible and the hub of the cartridge is down.
Caution – Possible damage to components. You must enter the cartridges properly, or
else you might damage the HandBot or the drive or cause the library to stop operating.
Use only cartridges designed for the drives in your library.
7. Grip the handle and slide the magazine back into the CAP.
8. Close the CAP door making sure that the door is securely latched.
The HandBot systematically moves each cleaning and diagnostic cartridge from the
CAP to an empty reserved cell.
9. Monitor the Import/Export Console to verify the status of the import operation.
The “Operation completed” status indicates that the import cartridge operation is
completed.
10.After the import operation is complete, the HandBot audits the CAP.
To view a list of cleaning and diagnostic cartridges in the reserved cells, see “Display
Cleaning Cartridges” on page 111.
Note – If you want to import cleaning and diagnostic cartridges into reserved cells one
cartridge at a time, use the Recovery Move diagnostic utility. See “Move a Cartridge
From a Specified Location” on page 93.